48V 12.5A 600W All-in-One DC UPS with MODBUS – DIN Rail

48V 12.5A 600W All-in-One DC UPS with MODBUS – DIN Rail

  • 48V, 12.5A output (600W) with load priority operation
  • IUoU five-stage charging with Recovery, Bulk, Absorption, Boost, and Float
  • Supports Lead Acid, Gel, Li-Ion, and Ni-Cd batteries
  • Auxiliary connections for optional RJTEMP sensor and DPY351 Controller
  • Integrated MODBUS RTU (RS-485) with SCADA integration and parallel support
SKU: CBI4810A
Brand: AdelSystem

USD $829.57(USD $912.52 inc GST)

Note: Australian GST only applies to orders delivered within Australia. International orders are exclusive of GST. 

3 in stock (can be backordered)

Volume discounts are automatically applied when added to the cart.
Quantity Discount Per Unit Price
1-4 0% USD $829.57
5-9 5% USD $788.09
10+ 10% USD $746.61

Description

CBI4810A – 48V 12.5A 600W DIN Rail DC-UPS with MODBUS RTU

The CBI4810A is a high-performance 48V 12.5A DC-UPS delivering up to 600W of continuous output power. It integrates power supply, battery charger, and backup module in one DIN rail-mounted device, ensuring uninterrupted operation for demanding industrial and automation applications. Load priority ensures the load is always supplied first, with the battery supplementing during peak demand, reducing the need to oversize the power system.

Equipped with Battery Care technology, the CBI4810A offers IUoU five-stage charging (Recovery, Bulk, Absorption, Boost, and Float), constant voltage and current support, and automatic battery diagnostics. This optimises charging performance, extends service life, and allows recovery of flat or sulfated batteries. Built-in alarms and relay outputs provide immediate notification of battery and system faults.

The unit supports Open Lead Acid, Sealed Lead Acid, Gel, Li-Ion, and Ni-Cd batteries. It features AUX 1 for the optional RJTEMP temperature sensor, while AUX 2 supports connection to the DPY351 Controller (HMI with Ethernet) and MODBUS RTU integration with SCADA systems. A dedicated connector is also provided for the RTCONN Start from Battery cable. The CBI4810A also supports parallel connection via AUX 2 using the RJCONN45 cable, making it highly flexible for system scaling.

Features and Benefits

  • 48V, 12.5A output (600W) with load priority operation
  • IUoU five-stage charging with constant voltage and current support
  • Supports Lead Acid, Gel, Li-Ion, and Ni-Cd batteries
  • Auxiliary connections for RJTEMP sensor and DPY351 Controller
  • Integrated MODBUS RTU (RS-485) for SCADA integration
  • Supports parallel connection for system expansion

Key Applications

  • Industrial automation and process control
  • SCADA and telemetry systems
  • Fire detection and alarm systems (EN54-4 compliant)
  • Security and access control networks
  • Battery-backed communication and instrumentation systems

Approvals and Compliance

  • EN60950 / UL60950-1 / CSA C22.2 No. 60950-1-07
  • EN IEC 62368-1:2014/AC:2015
  • EN54-4 Fire detection and alarm systems
  • EN12101-10 Smoke and heat control systems
  • IEC/EN 61000-6-3 (EMC Emission)
  • IEC/EN 61000-6-2 (EMC Immunity)
  • DIN41773 (Charging cycle)

Additional information

Weight 1.55 kg
Dimensions 150 × 115 × 135 mm
Output Voltage (Nominal)

Output Power (Range)

Communications

, ,

Input Voltage

,

Output Terminals

Screw Terminals

Specifications

Specification Summary – CBI4810A

Input 115 – 277 Vac, single-phase; 90–305 Vac range; 47–63 Hz
Output Load 48 Vdc, 12.5A continuous; up to 25A with battery assist; 38A peak (4s)
Output Battery 48 Vdc, 12.5A charging current; Recovery 6–42 Vdc
Charging Modes IUoU five-stage; constant voltage; constant current; Recovery, Bulk, Absorption, Boost, Float
Battery Support Open Lead Acid, Sealed Lead Acid, Gel, Li-Ion, Ni-Cd
AUX Interface AUX 1 for RJTEMP sensor; AUX 2 for DPY351 Controller / MODBUS RTU
Communications RS-485 MODBUS RTU; parallel connection via AUX 2 (RJCONN45)
Protections Short-circuit, overload, reverse polarity, overvoltage, overheating, sulfated/flat battery detection, LVD
Environmental –25 to +70 °C operation (derating above 50 °C); –40 to +85 °C storage; 95% RH non-condensing; up to 6000 m altitude (derating above 2000 m)
Mechanical 150 × 115 × 135 mm (W × H × D); Weight: 1.55 kg; DIN rail mount; IP20 protection

This specification summary may contain errors. Please refer to the product datasheet for full specifications.

Software

Software Downloads

Frequently Purchased Together

Available stock shown is updated live from our warehouse, with stock ready to dispatch. In the unlikely event something has gone wrong, our team will get in touch.

Australian GST applies only to Australian customers. If you’re shipping outside of Australia, GST will automatically be removed at checkout.

Note: other taxes and duties may apply on import to other countries.

Orders for in-stock items are shipped by the next business day, often earlier. We use TNT for orders within Australia, and DHL for international shipping. Delivery times will vary based on destination.

Yes! All shipments (within Australia and international) are tracked. Tracking information will be emailed to you. If you don’t receive the email, please contact our team.

You May Also Like...

Choose Preferred Currency
Helios Power Solutions

Welcome to our Australian online store, with select products ready to ship worldwide. 

If you’re looking for our full range of distributed products, as well as custom solutions, please head over to the Helios Power Solutions Main Site.